Options

Options are device-global settings. The following Options are defined:

Option Name Hex Value

force-audit

0x01

command-audit

0x03

The data payload is Option-specific.

Force Audit

This Option is used to enable Force Audit mode which prevents the device from performing additional operations whilst the Log Store is full.

The Option accepts three different values:

  • 0x00: Option disabled

  • 0x01: Option enabled

  • 0x02: Option permanently enabled (only possible to turn off through factory reset)

Command Audit

This Option is used to enable or disable logging of specific commands. Logging commands has a noticeable impact on performance. By default logging is enabled for all operations.

The Option accepts three different values:

  • 0x00: Option disabled

  • 0x01: Option enabled

  • 0x02: Option permanently enabled (only possible to turn off through factory reset)

Multiple commands can be specified at once with the syntax C1 V1, C2 V2, ..., Cn Vn where Ci is the Command Code and Vi is the Option Value. An example of this syntax can be found at the Set Option Command description.